Pick a rhythm. Press Play. Watch the impulse leave the sinus node, wait in the AV node, and run down the His-Purkinje system. The strip and the ladder diagram draw at the same time. Drag on the strip to measure an interval.
| Mobitz I (Wenckebach) | Mobitz II | 2:1 | |
|---|---|---|---|
| PR before the drop | Gets longer beat by beat | Stays the same | Only one conducted beat per cycle. No trend to see. |
| PR after the drop | Shortest PR of the group | Same as before the drop | Same every time |
| Usual level | AV node | His-Purkinje | Either. Find it with clues. |
| QRS | Usually narrow | Usually wide (bundle branch block) | Narrow favors node. Wide favors infranodal. |
| Pause | Less than 2 × the P–P interval | Exactly 2 × the P–P interval | Exactly 2 × the P–P interval |
| Atropine or exercise | Gets better | Gets worse (more P waves hit a tired system) | Nodal: better. Infranodal: worse. |
| Risk | Low. Often vagal, drug or sleep. | High. Can go to complete block and asystole. | Depends on level |
Two kinds of tissue carry the impulse. They fail in two different ways.
The upstroke uses calcium channels. These channels recover slowly. If the next impulse comes early in recovery, it conducts more slowly. This is decremental conduction.
In Wenckebach, each conducted beat makes the next P wave arrive earlier in the node's recovery. So each PR is a little longer. At last one impulse finds the node still refractory. It stops. The pause lets the node recover fully, and the cycle starts again.
The upstroke uses sodium channels. These channels are all-or-none. The impulse conducts at full speed, or it does not conduct at all.
Diseased His-Purkinje tissue has a long refractory period, but no "slow zone". So the PR does not stretch before a drop. The block appears suddenly. That is why Mobitz II gives no warning.
Slow upstroke (calcium) = node can slow down. Fast upstroke (sodium) = Purkinje fires fully or not at all.
Read from right to left. The node curve rises slowly (PR stretches). The His-Purkinje line is flat, then ends in a wall (sudden block). Points 1→2→3 are the Wenckebach beats walking up the node curve.
Many real Wenckebach periods are "atypical": the increment is not smooth, or the last PR jumps. Trust the shortest-PR-after-the-pause rule more than the R–R pattern.
In 2:1 block you see only one conducted PR per cycle. You cannot see a trend. So you cannot name it Mobitz I or Mobitz II from the strip. Name it "2:1 AV block". Then find the level.
Atropine speeds the sinus node and speeds the AV node. It does not help diseased His-Purkinje tissue. More P waves now reach a tissue that still has a long refractory period. So 2:1 can become 3:1, and the ventricular rate falls. Exercise does the same.
Look at the P wave before the pause. If it comes early (often hidden in the T wave) and has a different shape, it is a non-conducted PAC. The AV node was still refractory. That is normal physiology. Mobitz II needs a P wave that is on time. Try "Mimic · blocked PAC" in the lab.
The sinus rate slows at the same moment the PR stretches or a P wave drops. Think sleep, vomiting, pain, suction. This is the node, not His-Purkinje disease, even if the PR looks constant. Clue: the P–P interval lengthens.
Two or more P waves in a row do not conduct (3:1, 4:1), but some still conduct with a fixed PR. This is not complete heart block. Treat it like Mobitz II: the block is usually infranodal.
Mobitz I can occur in the His-Purkinje system (rare; small PR increments, wide QRS). Mobitz II can occur inside the His bundle with a narrow QRS. Concealed junctional or His extrasystoles can fake both. Pattern names describe the strip; the EP study tells the level.
Mobitz I: the AV node is a tired gatekeeper. It gets slower and slower, then takes a break. Mobitz II: a broken wire. It works, works, works, then nothing.
Two T's for type two. The block is low (His-Purkinje). It needs a pacemaker.
The most reliable Wenckebach sign. Compare the PR just after the pause with the PR just before it.
Nodal block tells the truth and gets better. Infranodal block gets worse. Use it in your head on the exam; use pacing at the bedside when the QRS is wide.
Do not ask "Mobitz I or II?" Ask "node or below?" Check the QRS width and the PR of the conducted beat.
The same year Einthoven won the Nobel Prize for the ECG, Mobitz used the ECG to split second-degree block into two types.
These blocks were described before the ECG was in clinical use. The first descriptions came from pulse tracings.
Dutch internist
He studied a patient's irregular radial pulse with a mechanical pulse recorder. He saw the interval between atrial and ventricular activity grow beat by beat until one beat failed. He did this without an ECG.
Bonus hook: in 1914 a patient told him that quinine stopped his own atrial fibrillation. Wenckebach reported it, and this observation led to quinidine as an antiarrhythmic.
Read about WenckebachPhysician, Liverpool
From jugular venous pulse tracings, he described dropped beats without progressive delay first. This is the pattern we now call Mobitz II.
Read about the history of Mobitz blockGerman physician
He used the ECG to sort second-degree block into type I (progressive PR) and type II (fixed PR). He saw that type II more often progressed to complete heart block. A century later, that is still the reason we pace it.
Read about MobitzHistorical facts on this page are marked for second-reader verification against the primary papers before publication.
Source: 2018 ACC/AHA/HRS Guideline on Bradycardia and Cardiac Conduction Delay. Check for an update at every quarterly review.
| Situation | Action | Class |
|---|---|---|
| Acquired Mobitz II, high-grade AV block or complete heart block, not from a reversible or physiologic cause | Permanent pacemaker, with or without symptoms | I |
| Asymptomatic first-degree block, Mobitz I, or 2:1 block believed to be at the AV node | Do not implant a pacemaker (it can cause harm) | III: Harm |
| Mobitz I or 2:1 at the node, with symptoms clearly caused by the block | Permanent pacing is reasonable | 2a |
| AV block from a reversible, non-recurring cause (drug toxicity, Lyme carditis, hyperkalemia) | Treat the cause first. Do not implant a permanent pacemaker if the block goes away. | III |
Watch these blocks in the full EP Lab, with intracardiac recordings: Mobitz I · Mobitz II · 2:1 nodal · 2:1 infranodal.
Then test yourself on real ECGs in Code ECG.
Last reviewed 2026-11-18 · Educational content, not medical advice.