ECG Library / AV conduction / Second-degree AV block
29 · Mobitz I (Wenckebach) 30 · Mobitz II 31 · 2:1 AV block Draft v0.1 · second-reader review pending

Second-degree AV block: Mobitz I, Mobitz II and 2:1

The bottom line

Conduction lab

Pick a rhythm. Press Play. Watch the impulse leave the sinus node, wait in the AV node, and run down the His-Purkinje system. The strip and the ladder diagram draw at the same time. Drag on the strip to measure an interval.

atria ventricles SA AV node His LBB RBB
This beat · PR—
AH (node) + HV (below)—
P waves / QRS—
Block level—
AV node (AH)His-Purkinje (HV)⊥ = impulse blocked herePaper speed 25 mm/s · 10 mm/mV · simulated tracing
Calipers: drag across the strip

Side by side

Mobitz I (Wenckebach)Mobitz II2:1
PR before the dropGets longer beat by beatStays the sameOnly one conducted beat per cycle. No trend to see.
PR after the dropShortest PR of the groupSame as before the dropSame every time
Usual levelAV nodeHis-PurkinjeEither. Find it with clues.
QRSUsually narrowUsually wide (bundle branch block)Narrow favors node. Wide favors infranodal.
PauseLess than 2 × the P–P intervalExactly 2 × the P–P intervalExactly 2 × the P–P interval
Atropine or exerciseGets betterGets worse (more P waves hit a tired system)Nodal: better. Infranodal: worse.
RiskLow. Often vagal, drug or sleep.High. Can go to complete block and asystole.Depends on level

Why the AV node stretches and the His-Purkinje system snaps

Two kinds of tissue carry the impulse. They fail in two different ways.

AV node slow-response tissue

The upstroke uses calcium channels. These channels recover slowly. If the next impulse comes early in recovery, it conducts more slowly. This is decremental conduction.

In Wenckebach, each conducted beat makes the next P wave arrive earlier in the node's recovery. So each PR is a little longer. At last one impulse finds the node still refractory. It stops. The pause lets the node recover fully, and the cycle starts again.

His-Purkinje fast-response tissue

The upstroke uses sodium channels. These channels are all-or-none. The impulse conducts at full speed, or it does not conduct at all.

Diseased His-Purkinje tissue has a long refractory period, but no "slow zone". So the PR does not stretch before a drop. The block appears suddenly. That is why Mobitz II gives no warning.

Action potentials

Slow upstroke (calcium) = node can slow down. Fast upstroke (sodium) = Purkinje fires fully or not at all.

Recovery curve: conduction time vs. how early the impulse arrives

Read from right to left. The node curve rises slowly (PR stretches). The His-Purkinje line is flat, then ends in a wall (sudden block). Points 1→2→3 are the Wenckebach beats walking up the node curve.

Three classic Wenckebach clues (fellow level)

  1. The biggest PR jump is the second beat. After that, each increment is smaller.
  2. So the R–R intervals get shorter before the pause. This "group beating" is a footprint you can see from across the room.
  3. The pause is less than two P–P intervals, because the pause contains the total PR increment.

Many real Wenckebach periods are "atypical": the increment is not smooth, or the last PR jumps. Trust the shortest-PR-after-the-pause rule more than the R–R pattern.

The 2:1 puzzle: where is the block?

In 2:1 block you see only one conducted PR per cycle. You cannot see a trend. So you cannot name it Mobitz I or Mobitz II from the strip. Name it "2:1 AV block". Then find the level.

2:1 AV block Favors AV NODE • Narrow QRS • Long PR in the conducted beats • Wenckebach (3:2) elsewhere on the strip • Atropine / exercise → block gets better • Vagal maneuver → block gets worse • Inferior MI, beta-blocker, sleep, athlete Favors HIS-PURKINJE • Wide QRS (BBB, bifascicular block) • Normal PR in the conducted beats • Mobitz II elsewhere on the strip • Atropine / exercise → block gets WORSE • Vagal maneuver → may improve conduction • Syncope, anterior MI, TAVR, sarcoid Still unsure? An EP study measures the HV interval and finds the level directly.

Why atropine makes a low block worse

Atropine speeds the sinus node and speeds the AV node. It does not help diseased His-Purkinje tissue. More P waves now reach a tissue that still has a long refractory period. So 2:1 can become 3:1, and the ventricular rate falls. Exercise does the same.

Traps and mimics

Blocked PAC is not Mobitz II

Look at the P wave before the pause. If it comes early (often hidden in the T wave) and has a different shape, it is a non-conducted PAC. The AV node was still refractory. That is normal physiology. Mobitz II needs a P wave that is on time. Try "Mimic · blocked PAC" in the lab.

Vagal AV block

The sinus rate slows at the same moment the PR stretches or a P wave drops. Think sleep, vomiting, pain, suction. This is the node, not His-Purkinje disease, even if the PR looks constant. Clue: the P–P interval lengthens.

High-grade (advanced) AV block

Two or more P waves in a row do not conduct (3:1, 4:1), but some still conduct with a fixed PR. This is not complete heart block. Treat it like Mobitz II: the block is usually infranodal.

Not every Mobitz pattern is where you think

Mobitz I can occur in the His-Purkinje system (rare; small PR increments, wide QRS). Mobitz II can occur inside the His bundle with a narrow QRS. Concealed junctional or His extrasystoles can fake both. Pattern names describe the strip; the EP study tells the level.

Make it stick

"Tired gatekeeper vs. broken wire"

Mobitz I: the AV node is a tired gatekeeper. It gets slower and slower, then takes a break. Mobitz II: a broken wire. It works, works, works, then nothing.

Type II = Too low, Too dangerous

Two T's for type two. The block is low (His-Purkinje). It needs a pacemaker.

"Shortest PR lives after the pause"

The most reliable Wenckebach sign. Compare the PR just after the pause with the PR just before it.

Atropine is a lie detector

Nodal block tells the truth and gets better. Infranodal block gets worse. Use it in your head on the exam; use pacing at the bedside when the QRS is wide.

2:1 = 1 question

Do not ask "Mobitz I or II?" Ask "node or below?" Check the QRS width and the PR of the conducted beat.

1924

The same year Einthoven won the Nobel Prize for the ECG, Mobitz used the ECG to split second-degree block into two types.

The people behind the names

These blocks were described before the ECG was in clinical use. The first descriptions came from pulse tracings.

1899 Karel Frederik Wenckebach (1864–1940)

Dutch internist

He studied a patient's irregular radial pulse with a mechanical pulse recorder. He saw the interval between atrial and ventricular activity grow beat by beat until one beat failed. He did this without an ECG.

Bonus hook: in 1914 a patient told him that quinine stopped his own atrial fibrillation. Wenckebach reported it, and this observation led to quinidine as an antiarrhythmic.

Read about Wenckebach
1906 John Hay

Physician, Liverpool

From jugular venous pulse tracings, he described dropped beats without progressive delay first. This is the pattern we now call Mobitz II.

Read about the history of Mobitz block
1924 Woldemar Mobitz (1889–1951)

German physician

He used the ECG to sort second-degree block into type I (progressive PR) and type II (fixed PR). He saw that type II more often progressed to complete heart block. A century later, that is still the reason we pace it.

Read about Mobitz

Historical facts on this page are marked for second-reader verification against the primary papers before publication.

So what? Guideline actions

Source: 2018 ACC/AHA/HRS Guideline on Bradycardia and Cardiac Conduction Delay. Check for an update at every quarterly review.

SituationActionClass
Acquired Mobitz II, high-grade AV block or complete heart block, not from a reversible or physiologic causePermanent pacemaker, with or without symptomsI
Asymptomatic first-degree block, Mobitz I, or 2:1 block believed to be at the AV nodeDo not implant a pacemaker (it can cause harm)III: Harm
Mobitz I or 2:1 at the node, with symptoms clearly caused by the blockPermanent pacing is reasonable2a
AV block from a reversible, non-recurring cause (drug toxicity, Lyme carditis, hyperkalemia)Treat the cause first. Do not implant a permanent pacemaker if the block goes away.III

Bedside: nodal block (narrow QRS)

  • Stop AV-nodal blockers. Check digoxin level and potassium.
  • Look for inferior MI, Lyme, sleep apnea, high vagal tone.
  • If unstable: atropine first.

Bedside: infranodal block (wide QRS)

  • Monitor with pacing pads on the chest.
  • Atropine may not help and may make the block worse.
  • If unstable: transcutaneous pacing, then transvenous pacing. Call EP.

Practice

Watch these blocks in the full EP Lab, with intracardiac recordings: Mobitz I · Mobitz II · 2:1 nodal · 2:1 infranodal.

Then test yourself on real ECGs in Code ECG.

References

  1. Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay. J Am Coll Cardiol. 2019;74:e51–e156.
  2. Barold SS, Hayes DL. Second-degree atrioventricular block: a reappraisal. Mayo Clin Proc. 2001;76:44–57.
  3. Surawicz B, Childers R, Deal BJ, Gettes LS. AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram, part III: intraventricular conduction disturbances. J Am Coll Cardiol. 2009;53:976–981.
  4. Wenckebach KF. Zur Analyse des unregelmässigen Pulses. Z Klin Med. 1899;37:475–488.
  5. Hay J. Bradycardia and cardiac arrhythmia produced by depression of certain of the functions of the heart. Lancet. 1906;1:139–143.
  6. Mobitz W. Über die unvollständige Störung der Erregungsüberleitung zwischen Vorhof und Kammer des menschlichen Herzens. Z Gesamte Exp Med. 1924;41:180–237.

Last reviewed 2026-11-18 · Educational content, not medical advice.